rauliruegas
Responses from rauliruegas
MC for Low Mass Tonearm Dear @michaellent : I owned the Frog and is a good cartridge designed many years ago. Now that you are looking for other cartridge than the Kleos then you have to look to Audio Technica that's a solid cartridge manufacturer of MM/LOMC for 60 yea... | |
MC for Low Mass Tonearm Dear @michaellent : Project designer recomend in its site the Ofrtofon Cadenza RED ( in this line the Black is trully good. ) that has lower compliance and higher weigth that the Kleos and its resonance frequency is around 11hz against the health... | |
Lyra and OMA @michaellent : Only take in count that the calculators in the net for the tonearm/cartridge frequency resonance takes the compliance at 10hz not 100hz. So, the Kleos has a compliance around 19 cu. Btw, I own the Kleos and never heard the Song... | |
Connecting a phonostage to a processor. @bwguy : Was not you who said your question was a dumb one?. I only post that agree with you. That's it. R. | |
Pioneer PL630- upgrading the phono cable? @musicearlyadopter : Not all AQ cartridges were made by Exel, its latest top of theline Fe5 model was manufactured by Scan-Tech. R. | |
Connecting a phonostage to a processor. Dear @bwguy : " However, I think my turntable actually sounds slightly better not using the bypass option. " If that is your experience then why ask about why open this thread when you have your self answer. Makes no sense. Yes adumb question to... | |
Pioneer PL630- upgrading the phono cable? Dear @musicearlyadopter : Scan-Tech is whom build Lyra cartriodges under its specifications. Your AQ cartridge was made it by Exel that not only makes Hana cartridges but many others marketed cartridges from several years. Exel has more than 40+... | |
Discuss The Viv Lab Rigid Arm Dear @frogman : You are rigth but the owners of that tonearm just posted that they like it and in reality no one gone in deep detail in their tonearms comparisons with selected LP tracks. I even posted to intactaudio if he could share the LPs... | |
Discuss The Viv Lab Rigid Arm Dear @intactaudio : Here are your main posts to me in even you talk about calculation where what I posted were all about LÖfgren A alignment calculations. It’s really weird that in no other of your posts but only in the last one mentioned abo... | |
Discuss The Viv Lab Rigid Arm My stupidity goes realy away. R. | |
Discuss The Viv Lab Rigid Arm Dear friends: No one yet? Here I go to null points calculation according with what I posted . R1: 60.325mm. R2: 146.05mm IEC Standard. First the numerator in the formula: 2 x 60.325 x 146.05 = 17,621 Now the denominator t... | |
Discuss The Viv Lab Rigid Arm @intactaudio : " for some reason you introduced this particular tangent in response to me simply mentioning in order to get two null points both overhang and offset are required. " Yes the VIV issue is useless for me but I return here because yo... | |
Discuss The Viv Lab Rigid Arm Dear @intactaudio : want to give you an example of two Löfgren A calculations where even that the EL of the tonearms is different an even that in both the overhag ( obviously ) is different the null points in both tonearms have the same value ( y... | |
Discuss The Viv Lab Rigid Arm @intactaudio : Your doubt but not Löfgren, Baerwald or Stevenson in their respective A and B alignments. " and not understanding its relationship to the discussion at hand serves little good. " Obviously speaking by your self understanding. ... | |
Discuss The Viv Lab Rigid Arm @intactaudio : " was about the requirement of both overhang and offset to get two null points. Without overhang which requires an effective length to calculate the two null points cannot exist. " That could be for you but not for Löfgren him ... |