Rare find Blowtorch Audio Preamp
There were only 38 of the CTC Blowtorch preamps made. The second one was specially made for a guy that only wanted a single stereo volume control. It was the only one made with the single volume control. 
My Cary amp - the story of a hum and a bug
bigkidz    1,928 posts   07-29-2019 9:27am    Trying powering up the amp with no interconnects connected to see if there is hum. Sometimes unshielded cables can cause the noise. If you are local to me New Jersey and can get the amp to me with th... 
My Cary amp - the story of a hum and a bug
But i do know that it is a design issue with the amp, for which Cary has a fix and they have fixed it in their newer version. Cary is not asking me to ship the amp back to them. They want to ship the harness/cable to me and they want me to pa... 
My Cary amp - the story of a hum and a bug
@ fiftyfifty  Your thread and posts to your thread are unclear. You say the hum is coming from the speakers and not mechanical hum/buzz/vibrating noise from the amp itself.But then you post this. fiftyfifty OP3 posts07-28-2019 6:51amSounds more... 
Grounding my Silvertone
bdgregory 1,590 posts 06-26-2019 7:19am The tube amp inside that model is likely a transformer-less design. I don’t think so.See page 15.http://lcweb2.loc.gov/master/mbrs/recording_preservation/manuals/Silvertone%20Radio%20(Parts%20List%...  
Grounding my Silvertone
Found this Web Link doing a quick Google search. http://lcweb2.loc.gov/master/mbrs/recording_preservation/manuals/Silvertone%20Radio%20(Parts%20List%... Not sure if it is the manual for the unit you have.If the manual is for the unit you have ther... 
Dedicated Circuit
So when my electrician installed the 20amp circuit breaker it is in fact right below two other 20amp breakers for the air conditioning units 20amp breakers,(two of them). 120V window air conditioners? If yes one is fed from the same Line as your ... 
High quality in-wall UL-C2 rated 10-gauge A/C wiring ?
ieales 361 posts 06-17-2019 8:59am Other than Class A, HiFi is not a continuous load. A ’typical’ tube amp is about 1A per 70W sum of both channels. No kidding? I would never of known that without you telling me. Is that what you took away from r... 
High quality in-wall UL-C2 rated 10-gauge A/C wiring ?
Voltage drop calculator.http://www.windsun.com/Hardware/Voltage_Calc.htm Distance or Conductor Size: .... (Distance) Single or Three phase: ........... (Single)Conductor Type: .... (Copper)Installation: ............. (Conduit)   .... Same for Rome... 
Dedicated Circuit
@ audiosaurusrex I think you misunderstood what the electrician said. In the typical US residential neighborhood the houses are fed from a single phase step down isolation type transformer. The secondary winding is center tapped. From the two out... 
Dedicated Circuit
audiosaurusrex OP 38 posts 06-15-2019 12:17pm So from what I’m told by the electrician because I have 100amp service there is no way to separate the “phase”. " there is no way to separate the “phase” What does that mean? 
High quality in-wall UL-C2 rated 10-gauge A/C wiring ?
@ron17Had you hired a reputable licensed electrician for the install he would have told you it does not meet the National Electrical Code for branch circuit wiring. CL2, Class 2 cable. CL2: This is a cable jacket fire resistance rating defined in... 
Anyone have this turntable issue?
Just a guess the mute circuity is ahead of the volume control circuitry section.You might want to contact Byrston Tech support.   Just curious did you try setting the SP3 to a different Line Level input and run a test?    
High quality in-wall UL-C2 rated 10-gauge A/C wiring ?
ieales356 posts 06-10-2019 1:46pm Table 310.15(B)(16): 60°C 75°C 90°C TW THWN THHN14ga 15A 20A 25AEncore Wire NM-B : Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN-2 with a heat-stabilized Nylon ... 
High quality in-wall UL-C2 rated 10-gauge A/C wiring ?
https://www.usawire-cable.com/pdf/nec-ampacities.pdf ** Unless specifically permitted in Section 240.4(E) through (G), the overcurrent protection shall not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper; or ...