jea48

Responses from jea48

HELP I think I have an electrical issue??
Ngjockey,A word of caution for Tim.... Any tampering/modifying of the furnace wiring could void his manufactures warranty.In most cases the manufacture only warrants the parts. The labor is picked up by the Heating/air conditioning mechanical cont... 
HELP I think I have an electrical issue??
Tim,Good that the gas Dryer did not cause a problem. That is a plus I would think.Before you contact the installer I suggest you do a little homework. I asked you to post who made your furnace and the model number if possible. I spent a little tim... 
HELP I think I have an electrical issue??
Tim,Installing an IG recept on an NM-B branch circuit will not have any benefit whats so ever. Using a ferrous metal box in place of the plastic box could actually degrade the sonics of you audio system.IG receptacles are mainly used in commercial... 
HELP I think I have an electrical issue??
... ,I am using 12/2 NM-B romex and so with this wire I can not correctly run an isolated ground??Tim, what is your understanding of an isolated ground? (note: these are no longer in my system) I heard suggestions of a Hubbel above but I think tha... 
HELP I think I have an electrical issue??
I am putting this in layman terms.LOL, not for my benifit I hope?I called my inspector today and asked him why I had to change the pastic boxes to metal on the IG outlets on a job he inspected for me 2 months ago. I am putting this in layman terms... 
HELP I think I have an electrical issue??
I know not all hospital outlets are not isolated. Most people here who are installing hospital grade are doing it for the isolated ground and unless wired correctly it will not be or can hurt someone. When an electrician or home owner installs it ... 
HELP I think I have an electrical issue??
Tmesselt,By chance do you have a gas fired cloths dryer?If so have your wife start the dryer while you listen for for any ignitor clicking noise sound from your speakers. 
HELP I think I have an electrical issue??
03-28-09: TmesseltWell, due to the fact that I was not wiring the isolated ground correctly I switched out my outlets to a standard 20amp outlet and the clicking is still there, but at least it is connected correctlyIf the receptacles are isolated... 
HELP I think I have an electrical issue??
Hevac1,Hospital grade receptacles do not have to be isolated ground type receptacles. The ever so popular Hubbell HBL 8300H hospital grade duplex receptacleHubbell IG8300 hospital grade duplex receptacle. 
HELP I think I have an electrical issue??
Myths 
HELP I think I have an electrical issue??
Oh, and I have also put the cheater plug on both amps and the clicking is still there.03-28-09: TmesseltWhy does that not surprise me...... 
HELP I think I have an electrical issue??
03-28-09: SnsCables are not going to fix this issue, picking up RFI from the furnace is the longest of long shots, and they didn't do it with the other amp, should tell you something. Ground potential is somehow different with new amps, I don't kn... 
HELP I think I have an electrical issue??
Tmesselt, The furnace is still covered under manufacture warranty for parts and labor. Give the furnace company that installed the furnace a call and tell them you are experiencing a problem with the furnace. LOL, no need to mention you didn't hav... 
HELP I think I have an electrical issue??
Except for I used Analysis Plus balanced interconnects before. Now that I am using the Genesis m60s which are unbalanced I am using a cheap pair NXG rca cables.Are the NXG rca cables shielded? Try another pair of ics that are shielded.Like I said ... 
back to ask again long sorry
03-20-09: Dog_or_manThe dedicated line has a safety ground. Dog_or_man,If I could make a couple of suggestions.First it appears part of your equipment is plugged into an old 2 wire branch circuit fed from the old Square D panel. The new 120V 3wire...