Component grounding


This is an Audio 101 question.

My Shunyata power conditioner has grounding posts. If one fancies supplemental grounding for one's components, beyond the ground wire in the power cord, one can run a wire from a chassis screw to the posts on the conditioner.

I’m not using the phono ground post on my integrated. Can I run a ground wire from there instead of a chassis screw?
rfprice

I also tried connecting the integrated and DAC to a single zone. No difference. 

 

So perhaps the integrated has a bad chassis ground? 

@rfprice - obviously there is some pretty strange grounding issues at play here and without being there it is difficult to advise on a solution

RE:..

I noticed that the hum kicked in when I connected the interconnects from the DAC to the integrated. It didn’t happen when the components were merely plugged in and powered on.

This indicates to me that the DAC is causing the issue not the integrated

- did you try grounding the neutral side of the output from the DAC as I suggested above??? i.e.

  1. try connecting a piece of wire to the ground point on the power conditioner
  2. Also try the ground point on an outlet
  3. then touch the other end to THE NEUTRAL COLLAR ONLY of any unused RCA socket on your amp
  4. the hum should disappear.

 

(Although this still doesn’t explain why the hum didn’t happen with either of the other two integrateds that I tried.) --

This is because the other two integraed amps had a different grounding scheme

 

You say it only hums if you bypass the pre section of the integrated

- wih both DAC and itegrated plugged into the shunyata in any combination

- but IT DOES NOT HUM if the integrated is plugged into the wall outlet

- and IT DOES NOT HUM if the pre section is NOT bypassed

So I think you have one of two possible solutions/choices.

Personally, I have ONLY EVER plugged my intergated or amp directly into the wall outlet - it allows the amp to excercise if full dynamic prowess.

I no longer use a power conditioner of any type, just a power distribution box with no "isolatoin" or filtering, but I do have a device like the Shunyata Venom Line Defender to protect the gear from surges - I also have a surge supressor on my electrical panel

Sorry I could not be of more assistance

Regards - Steve

 

@williewonka -- Thanks for all your advice thus far. It's much appreciated.

 

The neutral collar is the outer metallic 'shield', correct? If so, I did run a wire from the ground post on the Shunyata to the collar of an RCA of the integrated. No effect. You mention a similar operation with the DAC? 

 

You're right that it would make the most sense to just connect the integrated to the wall. But I like what the Shunyata does for the integrated. It doesn't suck a lot of juice so I don't think I'm losing much in terms of power. The other components are just a DAC and transport, so the Shunyata is not taxed. 

No no, I meant the preamp section of the integrated. It has a feature that let's you bypass the preamp section and use the output control on the DAC instead. When I did this, the hum came back. I don't know what that means, but you're right, the issue must reside with this particular amp because I've never had a hum otherwise. 

 

That sounds like a problem with the DAC. So if the amplifier is using its internal preamp, no hum, but if you connect the DAC to one of the inputs and use the preamp section's volume control- you have a hum (or buzz), right?

If yes it suggests an issue with the DAC. Since you did something to it as suggested in the posts above, it might be that there's more to it than a missing shoulder washer.

@atmasphere -- That's starting to seem to me like a likely explanation also. Plus the fact that the hum begins when the interconnects are inserted, not when everything is simply powered on. But I really didn't do anything to the DAC except switch the fuse. I'm very careful when doing any kind of operation with my equipment, and as I said earlier, there is no hum with the other two integrateds. One is a solid state, the other a tube.

 

I installed the nylon washer between the chassis and the ground wire ring. Then a ground washer screws against the ring. Is it worth trying another nylong washer between the ring and the ground washer?