rauliruegas

Responses from rauliruegas

Fidelity Research FR-64x
@lewm : As I said to you in my post ( one of my latests to chakster. ) you have nothing special on what you bougth not even that " unique unidin ".This I pasted from other forum:"""  in 1938 by LÖFGREN and his solutions through his calculations/e... 
Fidelity Research FR-64x
Because you have a different P2S mount distance. Try this: forgeret about the Sony protrcator and mount the PUA 7 at 235mm from the spindle and your  Feickert protractor will works with any alignment you want.R. 
Fidelity Research FR-64x
Dear @chakster : Own geometry? where do you read that or whom tell you?. Sony is a japanese manufacturer and used Stevenson A alignment. There is no " dedicated " protractor for it, the one you have is a protractor where the manufacturer gaves to ... 
Fidelity Research FR-64x
@chakster : I don’t know where is your common sense because I know for sure you are not a stupid gentleman as other.Look, you said that for you Stevenson A alignment is the way to go due that normally listen to 7" recordings and that’s why the nee... 
Fidelity Research FR-64x
Dear @ibelchev:  Your alignment is rigth and better that use the Stevenson A.Problem  when we use 247mm/250mm Löfgren A alignmemntb is not the tonearm/headshell but those cartridges you and other persons like: SPU or FR7. This is the real problem ... 
SAT 30K+$$ TONEARM: W O R T H T O H A V E I T ?
Dear @parrotbee : No, I don't heard it yet."""  clearly the SAT somehow does have those further returns. People who have the coin, having optimised everything else are always in pursuit of that tiny bit extra - """everything has that " returns ".... 
Fidelity Research FR-64x
@chakster : I'm not against which alignment is what you choosed. What I'm against it is that you posted " no prlem with Stevenson A alignment ", could be no problem for you but for almost all audiophiles exist a huge problem when in any tonearm th... 
Fidelity Research FR-64x
Dear @chakster @mulveling : You can try the cartridge/tonearm alignment in that FR with these parameters:overhang: 16.5mm, offset angle: 21.95° and P2S: 233.5mm. The distortion levels goes down again as tracking error. That is Löfgren A/Baerwald a... 
Audio-Technica ART 7
Again, have no idea between the 170 and the newest ART. Never mind.R. 
Fidelity Research FR-64x
Dear @chakster :  Well, 99.9999% of the audiophiles in the world always listen the normal LPs not 7"inch records.As I said Stevenson A is based on ignorance. Period.Btw, don't " listen " to that so stupid people like those germans that have no ide... 
Please Rate These Cartridges in Best Overall Order of Sonic Importance. Recommended Arms?
Dear @vinny55 : Please read carefully the @professorsvsu post.R. 
Please Rate These Cartridges in Best Overall Order of Sonic Importance. Recommended Arms?
Normally audio dealers don't permit to play with his new cartridges. Maybe if they have a demo sample, maybe.R. 
Audio-Technica ART 7
Dear @chakster : You have no idea why the ART 7 is way better than the 2000 ( I owned too. ). Your contributions always are better when you are not trying to sale one of your items.@confuse_upgraditis you can contact @dgarretson on the ART 7.R. 
Phono Preamps with "balls" ?
Dear @atmasphere : No, I don't missed but I was posting to him. I know very well the MAT discrete bipolar design. It could be a good alternative in your designs instead the out of production devices you were using.R. 
Fidelity Research FR-64x
Dear @chakster : " I use Stevenson by default with several tonearms, no problem with that. "I don’t know what you mean with no problem with that/Stevenson.Always is a real problem to align any tonearm with Stevenson A choice and the problem is tha...