rauliruegas
Responses from rauliruegas
BEST HARMLESS/SIGNATURELESS SPEAKERS CAPACITORS. Dear @paulcreed : I want to tell thank you because you did the effort and took your time to test Wima caps, at least you was the only gentleman that posted about.Appreciated too what you posted that reflect your honest kind of sound through those ... | |
Ikeda IT-407 tonearm geometry Dear @sdrsdrsdr : The Ikeda/FR specs are out of any alignment because they say overhang 12 mm, so they manipulate numbers.My take is to make the alignment according the P2S distance I posted and 13.28mm on overhang with an offset angle: 17.72°R. | |
Ikeda IT-407 tonearm geometry dEAR @sdrsdrsdr : """ Then Raul gave his recommendations for it407 and his p2s was shorter than recommended. I was just hoping for a more general consensus. """YOU HAVE A TOTAL MISUNDERSTOOD ON ALMOST ALL WHAT i POSTED HERE.It’s normal your misund... | |
Ikeda IT-407 tonearm geometry Dear friends: I posted that any one of us can manipulate in any tonearm any of the input alignment calculations and this means that each one of us can have a self " designed "/dedicated propietary alignment.That’s what the SAT tonearm did it when ... | |
Ikeda IT-407 tonearm geometry Dear @sdrsdrsdr : P2S: 293.718 . I used and use Löfgren A. Many years ago I used Löfgren B. Before I learned my tonearm set up always was made according manufacturer specs, not any more. https://www.vinylengine.com/tonearm_alignment_calculator_p... | |
Ikeda IT-407 tonearm geometry Dear @bukanona : That’s why Stevenson is no truwe alternative alignment and you can see it in the analog planet link that posted @sdrsdrsdr .Yes, the tracking error is independent of what your link stated but has a relationship that we can't just ... | |
Ikeda IT-407 tonearm geometry Dear @lewm : Your post has no sense for me and useless to this thread.Btw, 1938 was the year E.Löfgren alignment studies and in 1941 Baerwald appeared with the same Löfgren A solution, nothing new with.Who cares what was available back then. Certa... | |
Ikeda IT-407 tonearm geometry Dear @sdrsdrsdr : I posted in that Analog Planet thread because not even M.Fremer understand it the whole subject at 100%. I explain my take on the alignment issue and there I explained how was manipulated the parameters for that comparison align... | |
Ikeda IT-407 tonearm geometry Dear @sdrsdrsdr @edgewear : Löfgren was and is the gentleman who made the overall research that permits him to develops the formulas to make the critical tonearm/cartridge set up calculations parameters.What wanted Löfgren to calculate?, two main ... | |
Ikeda IT-407 tonearm geometry Dear @sdrsdrsdr : There is no problem with Ikeda geometry. The problem is to understand how the tonearm/cartridge set up alignment works.Forgeret about the Ikeda specs because you can change the effective length of any tonearm changing the pivot ... | |
Cartridge alignment with non slotted headshell? Dear @sdrsdrsdr @bukanona : Not Ortofon, they only gaves what the people in Japan ask for the 95% of those Ortofon cartridges were sold in Japan in those times: only business. Problem was developed in Japan and that's why Stevenson made what he m... | |
BEST HARMLESS/SIGNATURELESS SPEAKERS CAPACITORS. Dear friends: Outstanding, overwhelming, wonderful, paramount, astonishing, incredible, marvelous, gorgeous, facinating, jawless, amazing, ligth years a head, orders of magnitude, impressive, stunning, startling, sensational, unexpected, etc, etc.... | |
Cartridge alignment with non slotted headshell? Dear @sdrsdrsdr : You are rigth, in those kind of cartridges you just can't set up the zenith parameter.In those vintage times no one cares about not even the tonearm/cartridge manufacturers and Ortofon just gave and gives them what they ask for,... | |
Do I need an overhang gauge, in addition to a protractor to position cartridge correctly? Dear @millercarbon : """ Records are by far the best gateway drug into the world of high end audio. More and more people are turning to records because they hear the difference. """From some time now I disagree with you. I can't deny that the L... | |
Do I need an overhang gauge, in addition to a protractor to position cartridge correctly? Dear @millercarbon: "" Mine is to help guys get set up and enjoying music. Not navel gazing and worrying and spending more on mounting the cartridge than on the cartridge itself. ......... Why not, instead of making it harder and harder, ...""Y... |