6550 Tube Blew - A Few Questions


Hi. While listening to my system the other night, I noticed one of the power tubes for the right channel glowed extra bright, and static came through the speaker. I immediately shut down the amp, and haven't turned it back on.

Is it possible to check for damage to the other channel or other parts of the amp without installing a new tube to replace the blown one? I don't want to buy a matched pair and then discover that the amp has other damage.

Is it safe to test each channel with the other channel's tubes removed? Thanks!

Terry
128x128rwinner
Blown bias resistor would prevent tube or pair of tubes(for push-pull amp) to turn on.
Just checked the bias resistors. They were easy to spot - 5 watt 10 Ohm jobs. They tested for 10 ohms, all 4. I tested them out of the circuit. What else might I check?
Yea, I was hoping it was something simple like that. It fooled me, happening right after the tube blew. I guess I learned a little about my amp, though. Thanks a lot!