Damping Factor vs speaker sensitivity


Would the high Damping Factor of an integrated amplifier, combined with speakers with 94 dB of sensitivity, cause less good extension of the high frequencies?  For example a Hegel H190 with Damping Factor more than 4000 main power output stage.

audiosens
mike_in_nc, May be a greater smoothness give the impression that the high frequency did not sparkle as it is suppose to be, for my taste ?

A high damping factor (DF) is indicative of two things

The amplifier has a low output impedance (Which is inversely related to DF).
Generous application of negative feedback (NFB).

I have yet to come across a reasonable explanation as to why a DF of > than 40-50 or so offers any meaningful sonic benefit. I agree with the comments/perspective of @larryi above.

Charles

@audiosens 

 

Yes technically an amp can have a damping factor that is very high as it is measured at the amp terminals.  I was listing all the parasitic values in a system between the amp and speaker driver that makes this value meaningless.

I have met many DF zealots over the years, and I'm glad to read that obsession is not being amplified here.  A JBL engineer whote a paper in the late 60's debunking the idea with math and logic. 

The DF Debate

Floyd Toole, director of Engineering at Harman (JBL parent) reprises the effort for the next generation of the technically misinformed here:

DF Nonsense

If the goal of specifications is to characterize a component's ability to faithfully convey the signal fed at the input unaltered to the output, it's clear DF is not an important measure as long as it's above 40.  1000 is not better than 40!