how to run a 230 volt line from my panel??


I am getting a piece of equipment from europe that is set for 230v- I called the manufacturer and they said it can not be rewired to 110 I should simply run a 230 line= i already have 12 gauge wire ran to the stereo room- Is it just a matter of getting a 20 amp 230v breaker for my elec. panel-
Can i use the outlets I have now and a USA type power cord or what do I need to do?- thanks
fluffers
Just for perspective, every house has two separate 120 lines coming in. Combining them yields your 240. 240 appliances require two 'hot' leads, hence 240 volts.
BTW: the site I listed shows the configurations of IEC plugs, 125V(C-14) vs 230/250V(C-20). Note that the contacts of your expected 230V component's connector(chassis end) will be(most likely) horizontal, the ones on your 125V cord are vertical. Of course; you can change the IEC outlet, on your chassis or the IEC female, on your cord(http://www.vhaudio.com/connectors-ac.html#OyaideIEC).
First off... Is this a house, townhouse or condo? Seen the latter 2 with 208V, sort of 2/3 phase.

Second... What kind of equipment? Turntable, CDP, preamp or amp? If it's low power consumption, a step-up transformer (Topaz, Phoenix ...) might be easiest, cheapest and safest solution. Sometimes not the quietest. As far as I've seen, only a few turnatables are sensitive going from 50 to 60 Hz.
this is a cdplayer- running in a house- Since I already have the lines run to the room and room in the box it seems the prudent way to go-yes I was planning to ecut the ends of my current power cord and buy the correct connections for a 20 amp wall socket-p does this seem to make sense to everyone or am i missing something- thanks for all the advice--
Europe uses 50 Hz current rather than 60 Hz in North America. I would assume that most transformers nowadays can handle both, but it would be worth confirming.

Michael